A loft is the extra bedroom that does not take a square metre of garden, and the drawings decide whether it needs the council at all. We measure your roof, test it against the volume and roofline limits, and draw the Velux or dormer scheme for the right route. From £845, fixed before we start.

From £845 inc survey (£645 if you supply measured drawings)

  • MCIAT chartered architectural technologists
  • £2m professional indemnity insurance
  • LABC Partnered
  • ICO registered

Fixed fee, no VAT to add

Ask for a fixed fee

Photographs or current plans (optional)

Drag files here or browse your device

Up to 10 files, 90 MB in total: PDF, JPG, PNG or DWG

    Write to us before 3pm and we reply the same working day. Redraws are free until approval.

    02The fee

    One fixed fee, published

    Loft conversion drawings (Velux or dormer)

    from £845

    inc survey (£645 if you supply measured drawings). No VAT to add.

    Ask for your fixed fee

    What you get

    • A measured survey of the house and its roof, included in the price shown
    • A written verdict on the route: permitted development, certificate or planning
    • Existing and proposed floor plans, roof plan, elevations and sections
    • Stair, headroom and escape-route checks drawn in, not left to the builder
    • A second chartered technologist checks every sheet before it is sent
    • Changes the council asks for are redrawn at no charge

    A Lawful Development Certificate costs the council's fee of £274 for a householder case and goes to the council, not to us. There is no VAT to add to our fee.

    03How it runs

    From roof survey to a bedroom in the roof

    From roof survey to a bedroom in the roofConstraints check and roof volume sums; Measured survey of roof and stair; Velux, dormer or hip-to-gable options in 3D; Certificate or planning sheets checked and filed; Building regulations set for the builderi

    Constraints check and roof volume sums

    ii

    Measured survey of roof and stair

    iii

    Velux, dormer or hip-to-gable options in 3D

    iv

    Certificate or planning sheets checked and filed

    v

    Building regulations set for the builder

    The volume sums come first: they tell you whether a dormer is permitted or a planning case.
    Finished white-rendered rear house extension with large glazed doors

    40 m³

    Most extra roof volume on a terraced house; 50 cubic metres for any other house. Source: legislation.gov.uk

    Photograph: Brett Jordan

    04Extensions and lofts

    The volume sums that decide the route

    A loft conversion is permitted development only while the extra roof volume stays under 40 cubic metres on a terraced house and 50 on any other house. The enlargement may not stand above the highest part of the existing roof, may not extend past the plane of a roof slope that faces the street, and may not carry a balcony or raised platform.

    Where it can, the new roof is set back at least 20 cm from the original eaves, measured up the slope, with matching materials. We work these numbers on your survey before a line of the design is drawn, so you know on day one whether you are heading for a certificate or an application.

    A slate roof pitch with a rooflight set into it, seen from the roof of a house being renovated
    A rooflight set flush in a slate pitch: the lightest-touch way into the roof, with no volume added.Photograph: Gareth1953 All Right Now, CC BY 2.0

    05Extensions and lofts

    Conservation areas, mansards and the front slope

    In a conservation area the roof enlargement rights do not apply, so a dormer needs planning permission and the council will look hard at the street. Many period terraces in Islington, Camden and Kensington are better served by a rear dormer that stays below the ridge, or by a mansard roof where the council already accepts that form.

    A hip-to-gable or an L-shaped dormer adds floor area where a simple box dormer cannot, but each changes the roofline more. We draw the options side by side and show how each reads from the street and from the back of the neighbours.

    A flat-fronted Victorian house of 1898 in brick and stone with arched sash windows and a bay
    A flat-fronted Victorian house of 1898: the roof is part of the composition the council protects.Photograph: sludgegulper, CC BY-SA 2.0

    06Extensions and lofts

    Stairs, fire and the energy rules, drawn in

    Building control cares about how you get up and out. Where a full 2.0 m headroom cannot be reached over a loft stair, the guidance allows 1.9 m at the centre of the flight and 1.8 m at the side. Once a new storey sits above 4.5 m, the escape route down must be protected with fire-resisting doors and partitions, and every home needs mains-powered smoke alarms.

    The roof itself must meet a U-value of 0.15 W/m²K for new elements. We put these into the drawings, so your builder prices the insulation depth and the fire doors once, rather than finding them in a building control notice halfway through the job. Our building regulations drawings carry the detail.

    What a loft conversion costs us, and the councilDrawings with survey, our fee: £845; Certificate fee to the council: £274; Planning application fee to the council: £548; Changes the officer asks for: no charge£Drawings with survey, our fee£845£Certificate fee to the council£274£Planning application fee to the council£548£Changes the officer asks forno charge
    Council fees are those in force from 1 April 2026; they are paid to the council.

    07The record

    Figures that shape the job

    1. 40 m³

      Most extra roof volume on a terraced house; 50 cubic metres for any other house.

      Source: General Permitted Development Order 2015, Schedule 2, Part 1, Class B, checked 15 Oct 2026

    2. Front slope

      No enlargement may extend beyond a roof slope that forms the main elevation and fronts a highway.

      Source: General Permitted Development Order 2015, Schedule 2, Part 1, Class B, checked 15 Oct 2026

    3. 0.2 m

      Least set-back of the enlargement from the original eaves, measured up the slope, where practicable.

      Source: General Permitted Development Order 2015, Schedule 2, Part 1, Class B, checked 15 Oct 2026

    4. Ridge

      No part of the enlarged roof may be higher than the highest part of the existing roof.

      Source: General Permitted Development Order 2015, Schedule 2, Part 1, Class B, checked 15 Oct 2026

    5. £274

      Half the householder fee, charged for a certificate of lawfulness for a proposed use or operation.

      Source: Ribble Valley Borough Council, national fee table from 1 April 2026, checked 17 Oct 2026

    6. 1.9 m

      Headroom accepted at the centre of a loft stair where 2.0 m cannot be reached, falling to 1.8 m at the side.

      Source: Approved Document K (2013), paragraph 1.13, checked 15 Oct 2026

    7. 4.5 m

      Height of the new floor above ground at which the whole escape route needs fire-resisting doors and walls.

      Source: Approved Document B, volume 1, paragraph 2.21, checked 15 Oct 2026

    8. 0.15

      Limiting U-value, in W/m²K, for a new roof element in an existing home.

      Source: Approved Document L, volume 1 (2021 with 2023 amendments), Table 4.2, checked 15 Oct 2026

    08Questions

    What clients ask before they instruct us

    Do I need planning permission for a loft conversion in London?

    Frequently not. A rear dormer on a house outside a conservation area is permitted development if it keeps within the volume and roofline limits. We prove it with a Lawful Development Certificate before you spend on the build.

    Velux or dormer: which should I choose?

    Roof windows add light but no floor space and need little consent. A dormer adds head height and floor area but changes the roof. Your survey shows whether the existing roof is tall enough to make a Velux scheme work.

    What is included in the price?

    The measured survey of the house, a full set of existing and proposed drawings, the certificate or planning paperwork and an independent check, from £845 with no VAT to add. Structural calculations are priced separately.

    Will the neighbours have to be told?

    Planning neighbours are consulted by the council. Separately, steel bearing on a shared wall is work to a party structure, which needs a party wall notice at least two months before it starts; we can prepare it for you.

    I live in a flat. Can you still draw a loft?

    Permitted development rights do not cover flats, so a loft above one needs a full application and the freeholder's consent. We draw for that route and flag the lease points early.

    Kensington street lined with brick townhouses and lit streetlamps beneath an orange dusk sky

    Send us the address of your house.

    We look up the conservation area, listing and Article 4 position, then reply with a fixed fee. A message before 3pm is answered the same working day.

    Loft Conversion Drawings London | From £845